Quick answer
FDA sorts every medical device into Class I, Class II or Class III based on risk and on the controls needed to show it is safe and effective. Class I is the lowest risk and gets general controls only. Class II adds special controls, and many Class II devices need a 510(k) before sale. Class III is the highest risk and most of those devices need premarket approval (PMA). Your class comes from a classification regulation in 21 CFR parts 862 to 892, which you find by searching FDA’s Product Classification database for your device type. The intended use you claim on the label and in your listing decides which regulation fits, so the same product can land in a different class if the claims change.
What a device class is not
- It is not a quality grade. A Class I device is not “less approved” than a Class II device. The class only sets which controls apply.
- It is not something you pick. FDA assigns classes by regulation; you find the regulation that matches your intended use.
- It is not the same as registration. Registering an establishment and listing a device does not mean FDA has reviewed or authorized the product.
Updated November 2026. Brands that sell massagers, heating pads, thermometers, toothbrushes, gloves, braces or test kits online run into device classification sooner or later, often when a marketplace asks for a 510(k) number or proof of FDA listing. This guide explains the three classes, how to find your device’s class and product code, what “510(k) exempt” really means, and what each class means for registration and listing. It is general information, not legal advice.
Table of Contents
- What are the three FDA medical device classes?
- What is a Class I medical device?
- What is a Class II medical device?
- What is a Class III device, and is there “level 3 FDA approval”?
- How do I find my device’s classification?
- What does 510(k) exempt mean?
- Can my claims change my device class?
- What does each class mean for registration, listing and fees?
- How Eva Commerce helps
- Frequently asked questions
What are the three FDA medical device classes?
Section 513 of the Federal Food, Drug, and Cosmetic Act set up a risk-based system. FDA has written classifications for about 1,700 generic types of devices and grouped them into 16 medical specialty panels. Each type sits in one of three classes:
| Class | Risk level (FDA wording) | Controls that apply | Usual route to market |
|---|---|---|---|
| Class I | Lowest risk (low to moderate) | General controls | Most are 510(k) exempt; registration and listing still apply |
| Class II | Moderate to high risk | General controls plus special controls | Many need a 510(k); some are exempt |
| Class III | Highest risk | General controls plus premarket approval | PMA, unless an older 510(k) route still applies |
General controls apply to every class. They cover adulteration and misbranding, establishment registration and device listing, premarket notification where required, banned devices, notification and recall remedies, records and reports such as adverse event reports, and good manufacturing practice requirements. Special controls are extra requirements written for a Class II device type, such as performance standards, labeling rules or testing. Class III devices are the ones that support or sustain life or present a potential unreasonable risk, so FDA reviews their safety and effectiveness data before sale.
What is a Class I medical device?
A Class I device is one where general controls alone give reasonable assurance of safety and effectiveness. FDA says roughly 572, or 74%, of Class I device types are exempt from premarket notification. A few examples straight from the classification regulations:
- Manual toothbrush (21 CFR 872.6855): Class I, 510(k) exempt, and exempt from most good manufacturing practice requirements if not labeled sterile, except records and complaint files.
- Powered toothbrush (21 CFR 872.6865): Class I, 510(k) exempt within the limits in 872.9.
- Therapeutic massager (21 CFR 890.5660): Class I, 510(k) exempt, for an electrically powered device intended for medical purposes such as relieving minor muscle aches and pains.
- Non-powdered patient examination glove (21 CFR 880.6250): Class I, but only the finger cot version is 510(k) exempt. Exam gloves themselves still need a 510(k).
The glove example matters. Class I does not automatically mean “no FDA submission.” You have to read the regulation for your exact device type.
What is a Class II medical device?
A Class II device needs special controls on top of general controls. Many Class II devices need a 510(k), but some are exempt. Two examples:
- Powered heating pad (21 CFR 890.5740): Class II with special controls, 510(k) exempt subject to the limits in 890.9.
- Clinical mercury thermometer (21 CFR 880.2920): Class II, 510(k) exempt subject to 880.9. FDA uses this one as its own example; its three-letter product code is FLK.
FDA keeps exempting more Class II types. Under the 21st Century Cures Act it published exemptions for clinical electronic thermometers in June 2025 and for 14 product codes of clinical toxicology test systems on October 6, 2026. Exemptions come with conditions, so check the current regulation, not an old listing.
What is a Class III device, and is there “level 3 FDA approval”?
There is no “level 3” approval. Class III is simply the highest-risk class. Most Class III devices need a premarket approval (PMA) application, which is a review of scientific evidence of safety and effectiveness. A small number of older device types that were on the market before May 28, 1976 can still reach the market through a 510(k) until FDA calls for PMAs. Few consumer products sold online are Class III.
How do I find my device’s classification?
FDA’s own method is to find the classification regulation that matches your device:
- Write down the intended use and indications for use. What does the product do, and for which condition or user? FDA notes that indications can come from labeling and even from what is said during sale, so marketplace bullets and ad copy count.
- Search the Product Classification database by device name. Try several words (“brace” and “orthosis,” “stent” and “stents”). Each entry shows the device class, the regulation number, the three-letter product code and whether the type is 510(k) exempt.
- Read the regulation itself. The identification paragraph must match your product, and the classification paragraph tells you the class and any exemption. The general limits on exemptions sit in sections 862.9 through 892.9.
- Check similar devices. FDA suggests searching the 510(k), De Novo and PMA databases, or the registration and listing database, for a similar product’s product code. Most Class I and many exempt Class II devices will not appear in the premarket databases because they were never reviewed.
- Ask FDA if you are still unsure. The Division of Industry and Consumer Education answers device questions. For a formal written answer you can file a 513(g) request for information.
What does 510(k) exempt mean?
510(k) exempt means you do not need to send FDA a premarket notification before selling, as long as your device stays inside the exemption limits. It does not exempt you from anything else. Exempt devices are still subject to registration and listing, labeling, complaint and adverse event duties and, unless the regulation says otherwise, the Quality Management System Regulation in 21 CFR 820. An exempt device type can also lose the exemption if your version has a new intended use or different technology that the limits in the .9 sections exclude.
When a 510(k) is required, you show that your device is substantially equivalent to a legally marketed predicate. FDA issues an order finding it substantially equivalent, usually within 90 days, and you cannot market the device until you have that order. Contract manufacturers that build to someone else’s specifications do not file the 510(k); the firm whose specifications are used does. An importer does not need its own 510(k) when the foreign manufacturer already holds one for that device.
Can my claims change my device class?
Yes. Classification follows intended use, and intended use comes from your claims. A massager sold to “relieve minor muscle aches” fits the therapeutic massager regulation. The same motor sold with claims to treat a disease may fit a different regulation, or need a new submission. FDA’s general wellness guidance, updated in January 2026, explains when low-risk products that only promote a healthy lifestyle are not the focus of FDA device oversight. That policy depends on wellness-only claims and low risk, and it does not cover foods, supplements, cosmetics or drugs.
This is why marketplace copy deserves the same review as the label. A bullet point that adds a medical claim can move a product out of an exemption or into a different class.
What does each class mean for registration, listing and fees?
Owners and operators of establishments that make or distribute devices for the U.S. market register every year under 21 CFR 807 and list the devices made there, using the product code from the classification database. If the device needed a 510(k), De Novo or PMA, the listing carries that submission number. Foreign establishments also name a U.S. Agent.
FDA’s own fees for FY 2027 (October 1, 2026 to September 30, 2027) include:
- Annual establishment registration fee: $13,785.
- 510(k): $28,653, or $7,163 for a qualified small business.
- 513(g) request for classification: $8,596, or $4,298 for a small business.
- De Novo request: $191,020, or $47,755 for a small business.
These are government fees paid to FDA. They are separate from any service fee, and the small business rates require an approved Small Business Determination.
How Eva Commerce helps
Eva Commerce does not prepare 510(k), De Novo or PMA submissions and does not issue classification opinions. We handle the filings that sit on top of your classification: device establishment registration ($340 a year, plus FDA’s establishment fee), device listing ($50 per device), U.S. Agent service for foreign device establishments ($250 a year) and label review. Our device registration and listing guide walks through those filings, and every price is on our FDA compliance services page.
Because Eva also runs Amazon, Walmart, TikTok Shop and Shopify growth, we keep listing claims in line with the intended use your classification is built on. Book a call or call 858-315-2020 to check your device filings before your next launch.
Frequently asked questions
What is the difference between a Class 1 and Class 2 medical device?
Class I devices are the lowest risk and need only general controls; most are 510(k) exempt. Class II devices need general controls plus special controls, and many need a 510(k) before sale.
Are Class I medical devices regulated by FDA?
Yes. Class I devices are subject to general controls, including registration and listing, labeling, adverse event reporting and, unless exempted, quality system requirements. Being 510(k) exempt does not remove those duties.
How do I find the product code for my device?
Search FDA’s Product Classification database by device name. Each entry shows the three-letter product code, device class, regulation number and whether the type is 510(k) exempt.
What is a Class B or Class IIa medical device?
Those labels come from other countries’ systems. FDA uses only Class I, Class II and Class III, so a U.S. listing needs the FDA class and product code.
Can FDA tell me which class my device is in?
Yes. You can ask FDA’s Division of Industry and Consumer Education, or file a 513(g) request for a formal written answer. The FY 2027 513(g) fee is $8,596, or $4,298 for a small business.
Can Eva Commerce register and list my device?
Yes. Eva files device establishment registration ($340 a year) and device listing ($50 per device), and acts as U.S. Agent for foreign establishments ($250 a year). Book a call or call 858-315-2020.
Sources: FDA, Classify Your Medical Device; FDA, Regulatory Controls; FDA, Class I and Class II Device Exemptions; FDA, How to Determine if Your Product is a Medical Device; FDA, Product Classification database; FDA, Premarket Notification 510(k); FDA, General Wellness: Policy for Low Risk Devices (January 2026); FDA, Device Registration and Listing; FDA, MDUFA Fees FY 2027. Device examples from 21 CFR 872.6855, 872.6865, 880.2920, 880.6250, 890.5660 and 890.5740. General information, not legal advice.