Download "Amazon Advertising Playbook Strategies to Drive Profitable Growth". Get The PDF

Unique Device Identification (UDI) and GUDID: What Device Brands Must Label and Submit to FDA

FDA COMPLIANCE · MEDICAL DEVICES

Quick answer

Unique device identification (UDI) is FDA’s system for identifying medical devices from manufacturing through distribution to patient use. Under 21 CFR Parts 801 and 830, the device labeler (usually the manufacturer) must put a UDI, issued through an FDA-accredited issuing agency, on device labels and packages in plain text and barcode form, and submit device information to the Global Unique Device Identification Database (GUDID). A UDI has a fixed device identifier (DI) for the labeler and model and, when the label shows them, a production identifier (PI) for lot, serial number, expiration date or manufacturing date. GUDID stores only the DI. All UDI compliance dates have passed, and FDA says it is in the final phase covering the lowest risk devices.

Is GUDID the same as GTIN?

No. GUDID is FDA’s database of device identification records. A GTIN is a product number from GS1, one of three FDA-accredited issuing agencies. If your UDIs come from the GS1 system, the GTIN serves as the device identifier in your UDI, and that DI is the key to your device’s GUDID record. HIBCC and ICCBBA UDIs use their own formats.

Updated November 2026. Brands selling thermometers, pulse oximeters, braces, massagers, test kits or other medical devices in the U.S. eventually meet two acronyms: UDI on the package and GUDID behind it. This guide explains who must comply, what a UDI looks like, how GUDID accounts and submissions work, which consumer devices FDA treats differently and how this fits with registration and listing. It is general information, not legal advice.

What is unique device identification?

FDA’s UDI rule, published in 2013, requires most devices to carry a unique device identifier. FDA’s UDI Basics page defines it as a unique numeric or alphanumeric code with two parts:

  • Device identifier (DI): a mandatory, fixed portion that identifies the labeler and the specific version or model of the device.
  • Production identifier (PI): a conditional, variable portion that identifies the lot or batch, serial number, expiration date or manufacturing date when that information appears on the label.

The UDI must appear in two forms: easily readable plain text and automatic identification and data capture (AIDC) technology, such as a barcode. If the AIDC is not obvious on the label, the label must disclose it. Dates on device labels must use the YYYY-MM-DD format under 21 CFR 801.18. A device intended to be used more than once and reprocessed before each use must also carry the UDI as a permanent marking on the device itself.

Who is responsible for UDI: the brand or the factory?

The labeler. FDA defines a labeler as any person who causes a label to be applied to a device, or causes it to be modified, with the intent that the device will be commercially distributed without further label changes. In most cases that is the manufacturer, but it can be a specification developer, a convenience kit assembler, a repackager or a relabeler. Adding only a distributor’s name and contact information does not make someone a labeler. A private label brand that specifies the device and controls its label should assume it has labeler duties and confirm this with its manufacturer in writing.

How do you get a UDI?

FDA does not issue UDIs itself. Labelers get them by working with an FDA-accredited issuing agency. FDA currently lists three:

Issuing agency Device identifier in FDA’s UDI formats document
GS1 Numeric, 14 digits, data delimiter (01)
HIBCC Alphanumeric, 6 to 23 characters, data delimiter +
ICCBBA Alphanumeric, 16 characters, data delimiter =/

In GS1’s accreditation application published on FDA.gov, the UDI device identifier is represented by a GTIN, and production identifiers by GS1 application identifiers: (10) lot, (11) production date, (17) expiration date and (21) serial number. Each issuing agency’s system meets the same FDA rule, so pick one and use it consistently across your device versions and packaging levels.

What is GUDID and what goes into it?

The Global Unique Device Identification Database (GUDID) is administered by FDA and serves as a reference catalog for every device with a UDI. It contains only the device identifier, which serves as the key to the device’s information. It does not contain production identifiers, though it carries flags showing which PI types appear in the UDI. Each DI record follows FDA’s GUDID Data Elements Reference Table and business rules, covering items such as device name, company name, MR safety status, premarket submission numbers and a Global Medical Device Nomenclature (GMDN) term.

Timing rules in 21 CFR 830.330: the labeler must submit GUDID data no later than the date the device must bear a UDI, and submit updates whenever the information changes. An update is due no later than the date a device is first labeled with the changed information, or within 10 business days if the changed information does not appear on the label.

How do I request a GUDID account?

FDA says labelers of all classes of medical devices marketed in the U.S. may obtain a GUDID account. FDA’s process is:

  1. Prepare. Work with an issuing agency to assign UDIs, set labeling and records processes, gather the data required for each DI record, identify the people for GUDID user roles and get or verify the DUNS numbers FDA requires.
  2. Submit a GUDID New Account Inquiry to the FDA UDI Help Desk.
  3. Complete the GUDID New Account Request form the Help Desk emails back, and reply with it attached. An analyst reviews it and responds.
  4. Pick a submission method: manual entry in the GUDID web application, one record at a time, or HL7 SPL XML files through the FDA Electronic Submissions Gateway for bulk uploads, which requires a gateway account and testing. FDA’s GUDID guidance also allows a third-party submitter.

Do consumer devices sold online have to be in GUDID?

This is where many online brands land. Three FDA positions matter:

  • Class I GMP-exempt devices are excepted from UDI labeling under 21 CFR 801.30(a)(2). Check your device’s classification regulation.
  • A UPC can serve as the UDI for Class I devices. Under 21 CFR 801.40(d), a Class I device that bears a Universal Product Code on its label and packages is deemed to meet the UDI labeling requirements. A device may carry both a UPC and a UDI.
  • GUDID enforcement policy for consumer health products. In its 2022 compliance policy guidance, FDA said that at this time it does not intend to enforce GUDID submission requirements for “consumer health products,” meaning 510(k)-exempt Class I devices sold directly to consumers over the counter in stores or online. The policy does not cover Class I reserved devices, restricted (prescription) devices, implantable devices, life-supporting or life-sustaining devices, or certain reusable and wound care devices used only by healthcare professionals.

Class II and Class III devices get none of these breaks: they need a UDI on labels and packages and a GUDID record, unless a specific FDA exception or alternative applies. If you are unsure which class your product is, start with our medical device classification guide. FDA asks labelers with questions about the consumer health product policy to contact GUDIDSupport@fda.hhs.gov.

Can a device still carry an NDC or NHRIC number?

No, for devices labeled now. The UDI rule rescinded National Drug Code and National Health Related Item Code numbers assigned to devices, and FDA’s enforcement policy for legacy numbers applied only to devices labeled before September 24, 2023. Devices labeled on or after that date must not show those legacy numbers.

How do UDI and GUDID relate to registration, listing and clearance?

They are separate duties. Establishment registration and device listing under 21 CFR Part 807 tell FDA who makes the device and what it is, covered in our device registration and listing guide. Premarket review, such as a 510(k), is a different step again. A GUDID record does not mean FDA reviewed or authorized the device, and FDA may reject or remove GUDID data for a device that requires premarket clearance or approval but does not have it. For what each status means, see our answer on registered vs cleared vs approved. Anyone can search device records in AccessGUDID, the public database run with the National Library of Medicine. UDIs also make recalls faster to scope, as our recall classification guide explains.

How Eva Commerce helps

Eva Commerce does not issue UDIs or submit GUDID records, and we are not a law firm. We handle the FDA filings around them: device establishment registration is $340 per year plus the FDA establishment fee, device listing is $50 per device, U.S. Agent service for foreign establishments is $250 a year, and DUNS application support is $90. Label review is $340 (basic) or $590 (full compliance) per label. Prices are on our FDA compliance services page.

Because Eva also runs Amazon, Walmart, TikTok Shop and Shopify growth for 500+ brands, we can keep your device identifiers, listings and packaging consistent across channels. Book a call or call 858-315-2020 to review your device labeling and registrations.

Frequently asked questions

Is GUDID the same as GTIN?

No. GUDID is FDA’s database of device identification records. A GTIN is GS1’s product number. When a labeler uses GS1 as its issuing agency, the GTIN serves as the UDI device identifier that keys the GUDID record.

What devices require a UDI?

Most devices sold in the U.S. need a UDI on labels and packages. Exceptions include Class I GMP-exempt devices, and a UPC can serve as the UDI for Class I devices under 21 CFR 801.40(d).

Is GUDID mandatory?

For devices required to bear a UDI, yes under 21 CFR 830.300. FDA does not currently intend to enforce GUDID submission for 510(k)-exempt Class I consumer health products sold over the counter, with listed exceptions.

How do I request a GUDID account?

Prepare your UDIs, data and DUNS numbers, submit a GUDID New Account Inquiry to the FDA UDI Help Desk, then complete and return the New Account Request form it sends you.

What is the difference between a device identifier and a production identifier?

The DI is fixed and identifies the labeler and device model. The PI is variable and carries the lot, serial number, expiration date or manufacturing date shown on the label. GUDID stores only the DI.

Can Eva Commerce help with device FDA compliance?

Yes. Eva handles device establishment registration ($340 per year plus FDA fee), device listing ($50 per device), U.S. Agent service ($250 a year) and label review. Book a call or call 858-315-2020.

Sources: FDA, Unique Device Identification System (UDI System); FDA, UDI Basics; FDA, Global Unique Device Identification Database (GUDID); FDA, UDI Compliance Policies and UDI Rule Compliance Dates; FDA, UDI Policy Regarding Compliance Dates for Class I and Unclassified Devices (guidance); FDA, Contact an FDA-Accredited Issuing Agency; FDA, UDI Formats by FDA-Accredited Issuing Agency; GS1 accreditation application (FDA.gov); FDA, Request a GUDID Account; FDA, Prepare for GUDID; 21 CFR Part 801, Subpart B; 21 CFR Part 830; AccessGUDID (National Library of Medicine). General information, not legal advice.

Hai Mag Ceo

Hai Mag

Hai Mag, Founder & CEO of Eva Commerce, is a visionary leader in eCommerce and AI-driven automation with 20+ years of experience in business transformation, marketplace optimization, and growth hacking.
Amazon Ads Advanced Partner badge
Amazon Marketplace Developer Council badge
Shopify Partner badge
TikTok Shop Marketing Partner badge
Google Premier Partner badge
Meta Business Partner badge
Walmart Advertising Partner badge
Partner Badges 09